Fieldbus stepper drive
igus dryve D1 / D2 fieldbus stepper drive
igus motor controller for stepper, DC and EC/BLDC motors with CANopen or Modbus TCP, digital and analogue I/O and browser-based set-up; the D2 is rated to 21 A peak at 48 V.
Need this part, a replacement or a complete package? Our experienced UK engineering team helps you select, source and obtain the right products, with pricing, delivery coordination and after-sales support.
Pricing and availability
Get pricing, sourcing and replacement support
Need igus parts, a replacement or a suitable alternative? Send us a part number, or tell us what the machine needs to do. Our UK engineers will come back with the right product, pricing, lead time and delivery, whether that is the original part, a checked alternative or a complete axis.
- Original parts or a checked alternative
- Pricing, lead time and delivery in one reply
- Components, complete axes and ongoing support
No obligation. Add what you know and an engineer will help with the rest. Prefer to configure it? Build a specification.
Spec builder
Specify what you need instead of dryve D1 / D2
Select every part you need and answer the questions an applications engineer would ask. Our engineers use your specification to come back with the right products, pricing and lead times. You see your summary before we ask for any details.
Already know the part number? Send it to us directly.
- 1Products
- 2Performance
- 3Environment
- 4Volumes
- 5Your spec
What are you specifying?
Select everything you need. A motor, drive and gearbox can be specified together as one axis.
Key specifications
| Voltage (max) | 48 V |
|---|---|
| Fieldbus | CANopen, Modbus TCP; digital and analogue I/O |
| Peak current (max) | 21 A |
| Interface | integrated web server |
| Motor | stepper, DC, EC/BLDC |
Summarised in our own words from igus SE & Co. KG's published data; series maxima, individual models vary. Last checked 2026-10-30. Source 1 · Source 2
Notes on this data
igus says D1 and D2 are identical except for the housing.
Specify Motion is not affiliated with igus SE & Co. KG. igus and dryve D1 / D2 are used only to identify the product. Comparisons use published figures; always confirm against the current datasheet.
igus dryve D1 / D2 replacement and alternative options
Use these supply-network options as a starting point for an engineering check. We can also help source the original igus part. Published series figures do not establish an exact-model or drop-in replacement: confirm ratings, fit, interfaces and approvals for your application.
AMC's analogue servo drives for centralised control schemes: set up with DIP switches and potentiometers, commanded by +/-10 V or PWM. They span 10-400 VDC and 45-265 VAC, up to 150 A continuous and 250 A peak, in PCB, panel and vehicle formats. PCB extended-environment parts run -40 to +85 C.
| Published maximum | dryve D1 / D2 | AxCent Analogue Servo Drives (AB, AZ, … |
|---|---|---|
| Continuous current | — | 150 A |
| Peak current | 21 A | 250 A meets or exceeds |
Network-capable AMC digital drives spanning 10-747 VDC and 120-480 VAC, up to 150 A continuous and 250 A peak (27.4 kW peak power), in PCB, panel, machine and vehicle formats. They support almost any motor type and feedback, plus CANopen, EtherCAT, POWERLINK and Modbus.
| Published maximum | dryve D1 / D2 | DigiFlex Performance Servo Drives (DP,… |
|---|---|---|
| Continuous current | — | 150 A |
| Peak current | 21 A | 250 A meets or exceeds |
| Power | — | 27,400 W |
ADVANCED Motion Controls' ultra-compact, high power-density digital servo drives for 10-90 VDC systems, up to 100 A continuous and 200 A peak. They come in PCB, machine-embedded, panel and development-board formats, carry STO as standard, and run EtherCAT, CANopen or Ethernet/IP. Extended-environment models are rated -40 to +95 C.
| Published maximum | dryve D1 / D2 | FlexPro Digital Servo Drives (FE, FX, … |
|---|---|---|
| Continuous current | — | 100 A |
| Peak current | 21 A | 200 A meets or exceeds |
Figures are the highest published for each series and are not always measured the same way. A higher figure is not automatically a better choice: mounting, duty cycle, feedback, connectors and approvals matter too. An engineer will check the fit against your application before recommending anything.
Typical applications
What a fieldbus stepper drive is
A fieldbus stepper drive receives motion commands over a network such as CANopen, Modbus RTU, EtherCAT or another industrial Ethernet protocol, rather than step and direction pulses. Commands set position, velocity and current targets, and the drive reports status, position and faults back to the controller. Many support standard device profiles such as CiA 402, so a PLC or motion controller can treat them like servo axes. Open-loop and closed-loop versions are common.
When engineers choose a fieldbus stepper drive
Choose a fieldbus stepper drive for machines with several stepper axes controlled by a PLC or motion controller, where wiring, diagnostics and parameter management matter. It replaces many pulse cables with one network. The trade-offs are configuration effort and network dependency: the drive needs network set-up and configuration files, and a network fault stops all axes. For a single simple axis, pulse control can be quicker to commission.
How to specify the igus dryve D1 / D2
Send these with your enquiry and an engineer can confirm the right dryve D1 / D2 variant or an equivalent:
- Network protocol and device profile
- Supply voltage (V DC)
- Phase current (A)
- Open or closed loop
- I/O and homing functions
- Cycle time and synchronisation
- Configuration files and software
Common mistakes to avoid
- Choosing a protocol the controller does not support
- Not planning node addressing and network topology
- Overlooking cycle time for synchronised motion
- Missing configuration files for the controller
igus dryve D1 / D2: frequently asked questions
Can you help replace igus dryve D1 / D2 or source the original?
Send the full model code, quantity and required date. Our engineers can check original-part availability and assess suitable alternatives, including supply-network options where appropriate. We confirm compatibility and any changes needed before recommending a replacement.
What is the igus dryve D1 / D2?
igus motor controller for stepper, DC and EC/BLDC motors with CANopen or Modbus TCP, digital and analogue I/O and browser-based set-up; the D2 is rated to 21 A peak at 48 V. Published series figures include voltage 48 V, peak current 21 A. It is made by igus SE & Co. KG; Specify Motion can help source it or propose an equivalent.
Who makes the igus dryve D1 / D2?
The igus dryve D1 / D2 is made by igus (igus SE & Co. KG) and is listed here for engineers comparing options. Specify Motion is not affiliated with igus SE & Co. KG; brand names are used only to identify the product.
What is the voltage of the igus dryve D1 / D2?
The published series maximum voltage is 48 V. Individual models and sizes in the dryve D1 / D2 range vary, so check the exact variant against your duty cycle, mounting and environment, or ask our engineers to confirm the right size for you.
Is there an alternative to the igus dryve D1 / D2?
We can assess suitable replacement options. On published figures, ADVANCED Motion Controls AxCent Analogue Servo Drives (AB, AZ, AV, B, AVB) and ADVANCED Motion Controls DigiFlex Performance Servo Drives (DP, DZ, DV) are options to assess from our supply network. An engineer confirms the fit against your application before recommending anything.
What is CiA 402?
CiA 402 is a standard device profile for drives and motion control, originally for CANopen and also used on EtherCAT and other networks. It defines modes such as profile position, velocity and homing, and a standard state machine. Drives supporting it are easier to integrate with compatible controllers.
Is EtherCAT better than CANopen for stepper drives?
EtherCAT offers much higher bandwidth and precise synchronisation, which suits coordinated multi-axis motion. CANopen is simpler, cheaper and adequate for many point-to-point axes. Choose by controller support, number of axes, required cycle time and whether axes must be tightly synchronised.
Further reading: How to select a stepper drive · How to select a motion controller or plc · Servo drives
Other fieldbus stepper drive series
Engineer support
Let our experienced engineers do the hard work for you
Tell us how you use the igus dryve D1 / D2: the load, speed, duty and environment. Our engineers will confirm whether it is still the right part, find it for you, or propose an alternative that fits better.
- Reviewed by an engineer, not an autoresponder
- Like-for-like and better-fit alternatives
- Standard, modified and custom options
Prefer to configure it? Use the spec builder.
How it works
From enquiry to delivery
Send a part number or describe the application. Our engineers take it from there: the right product, a clear quotation, and delivery and support arranged.
- 01Tell us what you needSend a part number, or configure the application, quantities and timing.
- 02An engineer reviews itWe check the specification and find the original part, a checked equivalent or a complete axis.
- 03Receive your quotationProducts, pricing, lead time and compatibility notes in one reply.
- 04Order and deliveryWhen you are happy, the order is placed and delivery and after-sales support are arranged.