Optical incremental encoder
Baumer optoPulse EN580E.IL optical incremental encoder
58 mm optical incremental encoder with 1,024 to 4,096 pulses per revolution, TTL/RS422, HTL push-pull or SinCos 1 Vpp outputs, 6,000 rpm and -25 to +100 °C, in solid-shaft and through-hollow-shaft versions.
Key specifications
| Speed (max) | 6,000 rpm |
|---|---|
| Bore (max) | 12 mm |
| Ingress protection | IP54 flange side / IP65 housing side |
| Temperature | -25–100 °C |
| Data / bus | TTL/RS422, HTL push-pull, SinCos 1 Vpp |
| Supply | 5 V DC ±5 % (TTL version read) |
| Weight | 300 g |
| Radial load (max) | 80 N |
| Resolution | 1,024 / 2,048 / 4,096 ppr |
| Housing | 58 |
| Shaft | ø10 mm clamping flange, ø6 mm synchro flange, ø12 mm through hollow |
| Output frequency | ≤300 kHz (TTL) |
| Shock | 100 g, 11 ms |
| Vibration | 30 g, 10–2,000 Hz |
Summarised in our own words from Baumer Group's published data; series maxima, individual models vary. Last checked 2026-10-30. Source 1 · Source 2
Notes on this data
Figures from the EN580E.IL-SC10.GA1T1.01024.K page; pulse counts and output options from the product list. UL listed (E217823).
Specify Motion is not affiliated with Baumer Group. Baumer and optoPulse EN580E.IL are used only to identify the product. Comparisons use published figures; always confirm against the current datasheet.
Typical applications
Engineer support
Speak to our engineers about your project
Our experienced engineers are on hand, ready to help with your project. Whether you need the Baumer optoPulse EN580E.IL itself, help sourcing it, or a modified or custom design built around your load, speed and space, tell us what the machine has to do and we'll come back with the right option.
- Help sourcing optoPulse EN580E.IL and spares for installed machines
- Modified and custom designs when a catalogue part doesn't fit
- Complete axis: motor, drive, gearing and feedback matched together
What an optical incremental encoder is
An optical incremental encoder measures motion by shining light through or reflecting it from a disc or scale with fine graduations onto photodetectors. As the disc or scale moves, the encoder outputs two square-wave or sine-wave channels in quadrature, called A and B, plus an index pulse once per revolution or at reference marks. The counter in the drive or controller tracks position by counting edges from a home point. Optical encoders achieve very high resolution and accuracy.
When engineers choose an optical incremental encoder
Choose an optical incremental encoder for precise speed and position feedback where homing at power-up is acceptable, such as servo motors, stages and machine tools. They are widely compatible and cost effective. The trade-offs are contamination and power loss: dust, oil and condensation can obscure the optical path, and position is lost when power is removed. For harsh environments, magnetic or inductive encoders may suit better.
How to specify the Baumer optoPulse EN580E.IL
Send these with your enquiry and an engineer can confirm the right optoPulse EN580E.IL variant or an equivalent:
- Resolution (lines per revolution or µm)
- Output type: TTL, HTL or sin/cos
- Index or reference marks
- Shaft or hollow shaft size (mm)
- Maximum speed (rpm or m/s)
- Supply voltage (V)
- Environment and IP code
Common mistakes to avoid
- Choosing resolution above what the drive input can count
- Running long cables with TTL signals without line drivers
- Ignoring contamination in open optical designs
- Forgetting homing routines after power-up
Baumer optoPulse EN580E.IL: frequently asked questions
What is the Baumer optoPulse EN580E.IL?
58 mm optical incremental encoder with 1,024 to 4,096 pulses per revolution, TTL/RS422, HTL push-pull or SinCos 1 Vpp outputs, 6,000 rpm and -25 to +100 °C, in solid-shaft and through-hollow-shaft versions. Published series figures include speed 6,000 rpm, bore 12 mm, temperature -25 °C, temperature 100 °C. It is made by Baumer Group; Specify Motion can help source it or propose an equivalent.
Who makes the Baumer optoPulse EN580E.IL?
The Baumer optoPulse EN580E.IL is made by Baumer (Baumer Group) and is listed here for engineers comparing options. Specify Motion is not affiliated with Baumer Group; brand names are used only to identify the product.
What is the speed of the Baumer optoPulse EN580E.IL?
The published series maximum speed is 6,000 rpm. Individual models and sizes in the optoPulse EN580E.IL range vary, so check the exact variant against your duty cycle, mounting and environment, or ask our engineers to confirm the right size for you.
Is there an alternative to the Baumer optoPulse EN580E.IL?
Yes. Our engineers can propose an equivalent built around your load, speed and environment. An engineer confirms the fit against your application before recommending anything.
What is quadrature output on an incremental encoder?
Quadrature output provides two channels, A and B, offset by 90 electrical degrees. Comparing which leads gives direction, and counting edges on both gives four times the line count in resolution. An index pulse marks a reference position for homing.
What is the difference between TTL and HTL outputs?
TTL outputs use a 5 V differential signal, which suits high frequencies and is commonly used with line drivers. HTL outputs use a higher voltage swing, typically matched to a 10 to 30 V supply, which improves noise immunity on long cables. Match the output type to the drive or controller input.
Further reading: Absolute vs incremental encoders · How to select an encoder · Encoders and feedback
Other optical incremental encoder series
Spec builder
Specify what you need instead of optoPulse EN580E.IL
Select every part you need, answer the questions an applications engineer would ask, and see your summary before we ask for any details.
- 1Products
- 2Performance
- 3Environment
- 4Volumes
- 5Your spec
Engineer support
Our engineers are ready to help with your project
Tell us about your project and how you use the Baumer optoPulse EN580E.IL: the load, speed, duty and environment. An experienced engineer will review it and reply, normally within one working day.
- Reviewed by an engineer, not an autoresponder
- Like-for-like and better-fit alternatives
- Standard, modified and custom options
Prefer to configure it? Use the spec builder.